Analisis Energy Pompa Hisap Air Di Kawasan Ekonomi Khusus Palu

ANDRIAN BURHANUDDIN (2024) Analisis Energy Pompa Hisap Air Di Kawasan Ekonomi Khusus Palu. Sarjana thesis, Universitas Tadulako.

Full text not available from this repository.

Abstract

ANALISIS ENERGI POMPA HISAP AIR DI KAWASAN EKONOMI KHUSUS PALU
Andrian Burhanuddin, Dr. Alifi Yunar, S.T., M.T, dan, Siti Rahmi Oktavia, S.T., M.Eng.
ABSTRAK
Kebutuhan distribusi air baku di Instalasi Pengolahan Air di Kawasan Ekonomi Khusus Palu mendorong pengembangan pompa sentrifugal ini.Multimasi Kawasan Ekonomi Khusus Palu berjarak kurang lebih 1s2 kilo meter dari sumber lokasi IPA akan di sulap menjadi air bersih. Air dengan kapasitas 300 liter/detik. Spesifiksi pompa yang tepat diperlukan pendistribusian air baku ke IPA. Perhitungan yang akurat sesuai. Total head pompa, pompa daya, pemilihan impeller, dan energi pompa adalah semua factor yang di perhitungkan dalam analisis kebutuuhan air bersih. Jika desain dilakukan dengan cermat dan tepat, spesifikasi untuk pompa intake ini akan ditentukan sesuai dengan persyaratan. Dengan putaran motor sebesar 1450-2900 rpm dan kapasitas Q = 300 liter/detik dan Head total pompa = 117 m, dan pompa yang digunakan sebanyak 4 buah pompa utama dan 2 pompa cadangan karena pompa memiliki daya poros 75-150 kW dengan energi pompa 398,710 J, pada diameter minimumnya dan digunakan untuk jangka waktu yang lama.
Kata Kunci : Perencanaan, Air Bersih, Pompa Sentrifugal

ENERGY ANALYSIS OF WATER SUCTION PUMP KAWASAN EKONOMI KHUSUS PALU
Andrian Burhanuddin, Dr. Alifi Yunar, S.T., M.T, dan, Siti Rahmi Oktavia, S.T., M.Eng.
ABSTRACT
The need for raw water distribution at the Water Treatment Plant in the Kawasan Ekonomi Khusus Palu encourages the development of this centrifugal pump. Kawasan Ekonomi Khusus Palu, which is approximately 12 kilometers from the water source to the WTP location, will be transformed into clean water. water with a capacity of 300 liter/second. Exact pump specifications are required for the distribution of raw water to the WTP. Accurate calculations are appropriate. Total pump head, pump power, impeller selection, and pump energy are all factors taken into account in analyzing clean water needs. If the design is carried out carefully and precisely, the specifications for this intake pump will be determined according to the requirements. With motor rotation of 1450-2900 rpm and capacity Q = 300 liters/second and total pump head = 117 m, and the pumps used are 4 main pumps and 2 backup pumps because the pump has a shaft power of 75-150 kW with a pump energy of 398,710 J, at its minimum diameter and used for a long period of time.
Keywords: Planning, Clean Water, Centrifugal Pump

Item Type: Thesis (Sarjana)
Commentary on: Eprints 0 not found.
Divisions: Fakultas Teknik > Teknik Sipil
SWORD Depositor: Users 0 not found.
Depositing User: Users 0 not found.
Date Deposited: 22 Jan 2025 07:16
Last Modified: 06 Feb 2025 07:14
URI: https://repository.untad.ac.id/id/eprint/101616
Baca Full Text: Baca Sekarang